logo
Bioreactors

HABITAT ferment cct

SKU: GBA0010007585


Scope of delivery
  • HABITAT ferment cct S099
  • Tablet with software for bioreactor
  • HA.pl. Peltier cooling element
  • H 11 Mains cable with plug




ControllerFermenter
Operating modetimer, continuous and program operation
DisplayTablet PC
Operationtouch screen
Data memory size32 GB
Auto restart after power failureyes
Ethernet interfaceyes
Single use reactor interfaceyes
Thermostat interfaceyes
Ext. pump interfaceyes
Gravimetric feedingyes
Exponential feedingyes
Biomass feedingyes, with Excell Sensor
OPC UA interfaceyes
Filter heateryes
LED light panelAccessory
Stirring motoryes
Calibration guide temperatureyes
Calibration guide pHyes
Calibration guide pO2yes
pH - temperature compensationyes
Mode hose fillingyes
Stirrer control modeoff, manual, profile, Cascade-pO2 control, chaotic
Speed range1 - 2200 rpm
Speed deviation >= 100 rpm±2 %
Speed deviation <= 100 rpm±5 rpm
Speed displayTFT
Reversible direction of rotation yes
Timeryes
Timer displayTFT
Time setting range1 - 120 min
Heating blanketyes
Heat output250 W
Heat controlTFT
Temperature controlPID
Working temperature5 - 80 °C
Connection for ext. temperature sensorPT1000
Temperature displayyes
Temperature measuring range0 - 100 °C
Temperature measurement resolution 0.1 K
Temperature control accuracy ±0.2 °C
Temperature limit min.0 °C
Temperature limit max.110 °C
pH measurementyes
pH control modeoff, auto, profile
pH value displayTFT
pH measuring range0 - 14 pH
pH measurement resolution 0.01 pH
Accuracy of pH measurement±0.02 pH
Set resolution pH value0.01 pH
pH control accuracy±0.05 pH
Conncetion for pO2 sensoryes
pO2 control modeoff, manual, auto, profile
Measurement range pO2 min.0 %sat
Measurement range pO2 max.200 %sat
Resolution pO2 measurement0.01 %sat
Accuracy of pO2 measurement±0.3 %sat
pO2 control accuracy0.3 %sat
Conncetion for turbidity sensoryes
Turbidity control modeMonitoring
Conncetion for conductivity sensoryes
Conductivity control modeMonitoring
Conncetion for CO2 sensoryes
CO2 control modeMonitoring
Exhaust Gas Analyzeryes, with Blue Vary Sensor
OUR,CER,RQ calculationyes, with Blue Vary Sensor
RQ feedingyes, with Blue Vary Sensor
Digital pH sensoryes, with EasyFerm Bio Arc Sensor
Measuring Range min. digital pH0 pH
Measuring Range max. digital pH14 pH
Accuracy digital pH±0.02 pH
Digital DO sensoryes, with OxyFerm FDA Arc
Measuring Range min. digital DO0 %sat
Measuring Range max. digital DO200 %sat
Accuracy digital DO±2 %
Optical DO sensoryes, with VisiFerm RS485-ECS
Measuring Range min. optical DO0 %sat
Measuring Range max. optical DO300 %sat
Accuracy optical DO±1 %
Biomass sensoryes, with CGQ BioR Sensor
Measuring Range min. Biomass0.5 OD
Measuring Range max. Biomass50 OD
Digital Redox / ORP sensoryes, with EasyFerm Plus ORP Arc
Measuring Range min. digital ORP-1500 mV
Measuring Range max. digital ORP1500 mV
Digital biomass sensoryes, with Excell Sensor
Measuring Range min. digital biomass0 AU
Measuring Range max. digital biomass6 AU
Accuracy digital biomass±1 %
Viable Cell Density Sensorsyes, with Incyte Sensor
Measuring Range min. cell density5 x 10^5 cells/mL
Measuring Range max. cell density8 x 10^9 cells/mL
Accuracy cell density±1 %
Gas in connection Air6 mm
Gas out connection Air 6 mm
Gas in connection O26 mm
Gas out connection O26 mm
Gas in connection N26 mm
Gas out connection N26 mm
Gas in connection CO26 mm
Gas out connection CO26 mm
Aeration modecontinuous & automatic
Display flowratel/min, cc/min
Input pressure200 - 3000 mbar
Pressure out min.200 mbar
Pressure out max.1000 mbar
Flowrate Air min.100 cc/min
Flowrate Air max.20000 cc/min
Flowrate O2 min.100 cc/min
Flowrate O2 max.20000 cc/min
Flowrate N2 min.100 cc/min
Flowrate N2 max.20000 cc/min
Flowrate CO2 min.100 cc/min
Flowrate CO2 max.20000 cc/min
Measuring and control accuracy of the gas control units±2 % fsr
Peristaltic pumpyes
Numbers of pump heads4
Pump head functionAcid, Base, AntiFoam, Level
Pump headWatson Marlow 114DV
Number of pump tubes4
Number of pump rollers4
Flow rate min.0.3 ml/min
Flow rate max.270 ml/min
Flow rate control accuracy±0.3 ml/min
Pump Speed min.33 rpm
Pump Speed max.400 rpm
Pump reversible direction of rotationyes
Pump speed displayTFT
Inner tube diameter min. 0.5 mm
Inner tube diameter max.4.8 mm
Tube outer diamter min.4.1 mm
Tube outer diamter max.8.4 mm
Tube material Silicone
Tube hardness50 - 60 Shore A
Dimensions (W x H x D)224 x 624 x 405 mm
Weight14 kg
Packing unit1 pcs
Permissible ambient temperature5 - 40 °C
Permissible relative humidity80% (up to 31°C), decreasing linearly to max. 50 (@40°C)
Protection class according to DIN EN 60529IP 20
RS 232 interfaceyes
USB interfaceUSB-B
WiFi Interfaceyes
Voltage100 - 240 V
Frequency50/60 Hz
Power input300 W
Power input max.1100 W
Power input standby10 W
Fuse2x T5.0A 250V