CRUMA ECO2

APPLICATIONS

General chemistry involving small volumes of reagents or chemical compounds at ambient/moderate temperature in all types of laboratories:

  • Research laboratories
  • Quality control laboratories
  • Clinical and hospital laboratories
  • University and school laboratories…

in short, in any type of laboratory

Learn More:

GUARANTEED SAFE CHECKOUT
  • Stripe
  • Visa Card
  • MasterCard
  • PayPal
  • Apple Pay
SKU: GBACRECOGS Category:

Description

A ductless filtration fume hood created in response to a market that demands new products, but which is not willing to compromise on features, functions or quality. Our R+D+i department developed this model based on two fundamental premises: Economy and Ecology. Hence the name. A product that respects both the environment and the most demanding user. It is within this frame of action that the gas filtration fume hood ECO2 was born.

ECO2 underwent the same safety tests and controls as the rest of the ductless filtration fume hoods, responding to the stringent demands of our customers which all Cruma products offer.

Personnel Safety and Environmental Protection: Apart from completely protecting the person handling the material inside the cabinet, the chemical toxins produced are not released to the outside but remain inside the cabinet thanks to the filtration system formed by a variety of activated carbon filters.

Economic Savings and Easy to Set-Up: No expensive works are necessary to install conduits to extract the gas to the outside which means there are no additional costs and no need to interrupt a laboratory working at full capacity.

Flexible: These can be used in areas where it is difficult to extract contaminated air, such as the lower floors of buildings, and they can be placed in different locations, which it means that they can be easily relocated if needed.

Energy Savings: Unlike traditional extraction hoods, our fume hoods do not use the air conditioning equipment inside the laboratory, which substantially reduces energy costs. The aspirated air is not expelled outside but recirculated back into the laboratory free from contaminating substances.

Technical Data

Internal Sizes (width/depth/high)778x569x760
External Sizes (width/depth/high)798x600x1012
Filtration columns1
Filter number1 a 2
Fans1
Average volume of treated air/hour1757 m3/h
Average face velocity0.50 m/s
Internal volume of the cabinet0.287m3
Renewals inside the cabinet / min.9 ren./m
Total electrical power consumption47 W
Voltage-Frequency110-220 V / 50-60 Hz
LED light intensity900 Lux
UV Lamp–
Noise level50 dB
Weight65 Kg
Packaging volume0.42 m3